| Input Voltage |
90 ~ 264Vac 127 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF>0.9 at 75 ~ 100% load, 115Vac / 230Vac |
| Input Current |
0.4A/115Vac 0.2A/230Vac |
| Inrush Current |
40A/230Vac |
| Leakage Current |
0.5mA/240Vac |
| Output Voltage Adjustment Range |
-5% ~ 10%. Can be adjusted by internal potential meter SVR1 |
| Current Adjustment Range |
3% ~ -25%. Can be adjusted by internal potential meter SVR2 |
| Output Voltage Tolerance |
±10% |
| Line Regulation |
±3.0% |
| Load Regulation |
±5.0% |
| Set Up Time |
1500ms / 230VAC 3000ms / 115VAC at full load |
| Over Current Protection |
100 ~ 110% |
|
Constant current limiting, recovers automatically after fault condition is removed |
| Short Circuit Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
95°C ±5°C (TSW1) |
|
Shut down o/p voltage, re-power on to recover |
| Working Temperature |
-30°C ~ +50°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-40°C ~ +80°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.06%/°C (0°C ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 12min./1 cycle, period for 72min. each along X,Y, Z axes |
| Withstand Voltage |
I/P-O/P:3.75KVAC |
| Isolation Resistance |
I/P-O/P:100M Ohms/500VDC 25°C 70%RH |
| Safety Standards |
TUV EN61347-1, EN61347-2-13, CAN/CSAC22.2 No. 223-M91(except for 48V), IP64 approved |
| EMC |
Compliance to EN55015; EN61000-3-2 Class C (pin25W), Class D (>70% load) ; EN61000-3-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, Light industry level, criteria A |
| MTBF |
621.4Khrs min. MIL-HDBK-217F (25°C) |
| Dimensions |
145 x 47 x 30mm |