| Input Voltage |
90 ~ 264VAC |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
0.6A/115VAC 0.3A/230VAC |
| Inrush Current |
42A/230VAC |
| Leakage Current |
<0.75mA/ 240VAC |
| Power Factor |
PF>0.9 at 75 ~ 100% load, 115VAC / 230VAC |
| Voltage Tolerance |
±10% |
| Line Regulation |
±3.0% |
| Load Regulation |
±5.0% |
| Set Up Time |
1000ms / 230VAC 2000ms / 115VAC at full load |
| Over Current Proection |
100 ~ 110% |
|
Constant current limiting, recovers automatically after fault condition is removed |
| Short Circuit Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Working Temperature |
-30°C ~ +70°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 95% RH non-condensing |
| Storage Temperature, Humidity |
-40°C ~ +80°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0°C ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG::100M Ohms / 500VDC / 25/°C 70% RH |
| Safety Standards |
TUV EN61347-1, EN61347-2-13 approved, design refers to UL60950-1 |
| EMC |
Compliance to EN55015, EN61000-3-2 Class C (>75% load); EN61000-3-3 |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,EN61547, light industry level, criteria A |
| MTBF |
586.5Khrs min. MIL-HDBK-217F (25°C) |
| Dimensions |
101.6 x 50.8 x 28mm |