| Input Voltage |
90 ~ 264Vac 127 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF>0.93/230Vac PF>0.98/115Vac at full load |
| Input Current |
115Vac: 1.7A (1.2A for 3.3V) 230Vac: 0.75A (0.6A for 3.3V) |
| Inrush Current |
24A/230Vac, cold start |
| Leakage Current |
<2mA / 240Vac |
| Set Up, Rise Time |
1000ms, 30ms/230Vac 2000ms, 30ms/115Vac at full load |
| Hold Up Time (Typ.) |
24ms/230Vac 24ms/115Vac at full load |
| Line Regulation |
±0.5% |
| Load Regulation |
±1.0% |
| Over Load Protection |
130 ~ 160% rated output power. |
|
Fold back current limiting, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Working Temperature |
-20°C ~ +70°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-40°C ~ +85°C , 10 ~ 95% RH |
| Temperature Coefficient |
±0.05%/°C (0°C ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Rresistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety |
UL60950-1, TUV EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; ENV50204; |
|
EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A |
| MTBF |
111.7Khrs min. MIL-HDBK-217F (25°C ) |