Standards

General Specifications
| OUTPUT | |
|---|---|
| Rated Power | 700W |
| Max. Output Power | 800W for 180 sec. / 1050W for 10 sec./ surge power 1400W for 30 cycles |
| AC Voltage | Factory setting set at 230VAC 200 / 220 / 230 / 240VAC selectable by setting button S.W |
| Frequency | 50±0.1Hz 50/60Hz selectable by setting button S.W |
| Waveform | True sine wave (THD<3%) at rated input voltage |
| AC Regulation | ±3.0% |
| Saving Mode | Load <5W will be changed to standby mode |
| Front Panel Indicator | Battery voltage level, output load level, saving mode, fault and operation status |
| *************************** | |
| INPUT | |
| No Load Dissipation | <6W @ standby saving mode |
| Off Mode Current Draw | <1mA |
| Battery Types | Open & sealed Lead Acid |
| Input Bat. Polarity Protection | By internal fuse open |
| *************************** | |
| Over Temperature Protection | 75°C ±5°C |
| Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power diode | |
| Output Short Protection | Shut down o/p voltage, re-power on to recover |
| Over Load Protection | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. |
| Shut down o/p voltage, re-power on to recover | |
| GFCI Protection | None |
| Working Temperature | 0 ~ +40°C @ 100% load ; +60°C @ 50% load |
| Working Humidity | 20% ~ 90% RH non-condensing |
| Storage Temperature, Humidity | -30°C ~ +70°C / -22 ~ +158°F, 10 ~ 95% RH |
| Vibration | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | EN60950-1 |
| Withstand Voltage | Bat I/P-AC O/P: 3.0KVAC AC O/P- FG: 1.5KVAC |
| Isolation Resistance | Bat I/P-AC O/P, Bat I/P-FG:100M Ohms / 500VDC / 25°C / 70% RH |
| EMI Conduction & Radiation | Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark |
| EMS Immunity | Compliance to EN61000-4-2,3,8 ENV50204 |
TS-700-248D Specifications
| Part Number | Voltage (max/rated) | Power (watts) | Efficiency (%) |
|---|---|---|---|
| TS-700-248D | 230V | 700W | 91% |