| Input Voltage |
90 ~ 264Vac 135 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF>0.91 / 230Vac PF>0.95 / 115Vac at full load |
| Input Current |
2A/ 115Vac 1A/ 230Vac |
| Inrush Current |
70A/ 230Vac |
| Leakage Current |
1mA/ 240Vac |
| Set Up, Rise Time |
1000ms, 20ms / 230Vac 1000ms, 20ms / 115Vac at full load |
| Hold Up Time |
20ms / 230Vac 20ms / 115Vac at full load |
| Over Load Protection |
110 ~ 150% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
105 ~ 135% rated output voltage |
|
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
RTH30 > 100°C |
|
Shut down o/p voltage, re-power on to recover |
| Working Temperature |
0°C ~ +50°C (Refer to output load derating curve) |
| Working Humidity |
20% ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03% /°C (0~50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/°C 70% RH |
| Safety Standards |
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved |
| EMC |
Compliance to EN55022 Class B, FCC PART15 / CISPR22 Class B, CNS13438 Class B, GB9254 Class B; |
|
EN61000-3-2,3, GB17625.1; EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A |
| MTBF |
348.7Khrs min. MIL-HDBK-217F (25°C) |
| DC Plug |
PM1: 2.5 x 5.5 x 11mm, tuning fork type, center positive. Other types available by customer request. |
| DC Cable |
UL1185 14AWG 1000 ±50mm for 12V ~ 15V |
|
UL1185 16AWG 1200 ±50mm for 19 ~ 48V |