General Specifications
| INPUT VOLTAGE RANGE |
88~264VAC 47~63Hz; 124~370VDC |
| AC CURRENT |
2.5A/115V 1.5A/230V |
| INRUSH CURRENT |
COLD START 20A/115V 40A/230V |
| LEAKAGE CURRENT |
<1mA/240VAC |
| OVERLOAD PROTECTION |
CH1:105%~135% CH2:0.51~0.9A TYPE:CONSTANT CURRENT LIMITING RESET:AUTO RECOVERY |
| OVER VOLTAGE PROTECTION |
CH1:115%~135% TYPE:SHUTDOWN |
| TEMP. COEFFICIENT |
?0.03% / ?C (0~50?C) |
| SETUP, RISE, HOLD UP TIME |
2s, 90ms, 16ms/115VAC 1s, 90ms, 20ms / 230VAC |
| POWER FACTOR |
PF>0.92 |
| VIBRATION |
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms |
| WORKING TEMP., HUMIDITY |
-10?C~+60?C(REFER TO OUTPUT DERATING CURVE), 20%~90% RH |
| STORAGE TEMP., HUMIDITY |
-20?C~+85?C, 10%~95% RH |
| WEIGHT |
1Kg |
| SAFETY STANDARDS |
UL1950, TUV EN60950 APPROVED |
| EMC STANDARDS |
CISPR22(EN55022)CLASS B,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-3-2,-3 |
AD-155A Specifications
| Part Number |
Voltage (max/rated) | Current (amps) | Power (watts) | R&N (mV) | Efficiency (%) |
| AD-155A
|
14V
|
10.5A
|
152W
|
150mV
|
80%
|
|
|
13.3V
|
0.5A
|
|
|
|
AD-155A
| DC Voltage | Rated Current | Current Range | Rated Power | Ripple & Noise | Voltage ADJ Range | Voltage Tolerance | Line Regulation | Load Regulation | Efficiency | Over Voltage |
| 13.8V | 10.5A | 0-11.5A | 151.55W | 150mVp-p | 12-14.5V | ±2.0% | ±0.5% | ±0.5% | 80% | 15.87-18.63V |
| 13.3V | 0.5A | 0-0.5A | 151.55W | N/A | N/A | N/A | N/A | N/A | 80% | N/A |