ADS-5524 - ADS-5524
Home > Products > ADS-55 Series 55W Single Output with DC-DC Converter > ADS-5524
|
Standards
|
General Specifications
| INPUT VOLTAGE RANGE |
88~264VAC 47~63Hz; 120~370VDC |
| AC CURRENT |
1.6A/115V 1A/230V |
| INRUSH CURRENT |
COLD START 20A/115V 40A/230V |
| LEAKAGE CURRENT |
<1mA/240VAC |
| OVERLOAD PROTECTION |
105%~150% / 230VAC TYPE:PULSING-HICCUP SHUTDOWN RESET:AUTO RECOVERY |
| OVER VOLTAGE PROTECTION |
CH1:115%~135% TYPE:PULSE BY PULSE |
| TEMP. COEFFICIENT |
?0.03% / ?C (0~50?C) ON CH1 OUTPUT |
| SETUP, RISE, HOLD UP TIME |
1.6s, 50ms, 16ms/115VAC 800ms, 50ms, 60ms / 230VAC |
| VIBRATION |
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms |
| WORKING TEMP., HUMIDITY |
-10?C~+60?C(REFER TO OUTPUT DERATING CURVE), 20%~90% RH |
| STORAGE TEMP., HUMIDITY |
-20?C~+85?C, 10%~95% RH |
| SAFETY STANDARDS |
UL1950, TUV EN60950 APPROVED |
| EMC |
CISPR22 (EN55022) CLASS B, EN61000-3-2,3; EN61000-4-2,3,4,5,6,8,11; ENV50204
VERIFICATION |
|
ADS-5524
|
DC Voltage
|
Rated Current
|
Current Range
|
Rated Power
|
Ripple & Noise
|
Voltage ADJ Range
|
Voltage Tolerance
|
Line Regulation
|
Load Regulation
|
Efficiency
|
|
24V
|
2A
|
0-2.5A
|
58W
|
100mVp-p
|
21.6-26.4V
|
±1.0%
|
±1.0%
|
±1.0%
|
74%
|
|
5V
|
2A
|
0-4A
|
58W
|
100mVp-p
|
N/A
|
±3.0%
|
±0.5%
|
±0.5%
|
74%
|
|
 |
| Add this product to your ClipBook |