ID-50B - ID-50B
Home > Products > ID-50 Series 50W Isolated Dual Output AC-DC Enclosed Switching > ID-50B
|
|
General Specifications
| SETUP, RISE, HOLD TIME |
1.6s, 50ms, 20ms at full load |
| VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| AC CURRENT |
1A/115VAC 0.6A/230VAC |
| INRUSH CURRENT(max.) |
COLD START 18A/115VAC 36A/230VAC |
| LEAKAGE CURRENT |
<3.5mA / 240VAC |
| OVER LOAD |
105 ~ 150%/115VAC rated output power Protection type : Hiccup mode, recovers automatically after fau |
| OVER VOLTAGE |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| WORKING TEMP. |
-10 ~ +60?C (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85?C , 10 ~ 95% RH |
| TEMP. COEFFICIENT |
?0.03%/?C (0 ~ 50?C)on +5V output |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| SAFETY STANDARDS |
Design refer to UL1012 |
| WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Design refer to FCC Part15 |
| MTBF |
312.2K hrs min. MIL-HDBK-217F (25?C) |
|
ID-50B
|
DC Voltage
|
Rated Current
|
Current Range
|
Rated Power
|
Ripple & Noise
|
Voltage ADJ Range
|
Voltage Tolerance
|
Line Regulation
|
Load Regulation
|
Efficiency
|
Over Voltage
|
|
13.5V
|
1.8A
|
0.3-2A
|
48.6W
|
100mVp-p
|
12-15V
|
±1.0%
|
±0.5%
|
±0.5%
|
70%
|
17-21V
|
|
13.5V
|
1.8A
|
0.2A
|
48.6W
|
150mVp-p
|
12-15V
|
±2.0%
|
±0.5%
|
±0.5%
|
70%
|
17-21V
|
|
 |
| Add this product to your ClipBook |