General Specifications
| INPUT VOLTAGE RANGE |
90 ~ 264VAC 127 ~ 370VDC |
| INPUT FREQUENCY RANGE |
47 ~ 63Hz |
| AC CURRENT |
1.9A/115VAC 1.1A/230VAC |
| INRUSH CURRENT(max.) |
COLD START 24A/115VAC 40A/230VAC |
| LEAKAGE CURRENT |
<1mA / 240VAC |
| SETUP, RISE, HOLD TIME |
100ms, 35ms, 50ms/230VAC 100ms, 35ms, 12ms/115VAC |
| PROTECTION OVER LOAD |
115 ~ 150% of rate loadProtection type : Hiccup mode, recovers automatically after fault condition |
| PROTECTION OVER VOLTAGE |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| REMOTE ON/OFF |
RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off |
| WORKING TEMP., HUMIDITY |
-20 ~ +60°C (Refer to output load derating curve), 20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85°C , 10 ~ 95% RH |
| TEMP. COEFFICIENT |
?0.04%/ (0 ~ 50°C) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes |
| SAFETY STANDARDS |
UL60950, TUV EN60950 Approved |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
| HARMONIC CURRENT |
Compliance to EN61000-3-2,-3, Class A |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| MTBF |
355Khrs min. MIL-HDBK-217F (25?C) |
|