| Input Voltage |
88 ~ 132Vac / 176 ~ 264Vac selected by switch |
| Input Frequency |
47~63Hz |
| Power Factor |
>0.65 (with PFC series) |
| Input Current |
3A/115Vac 1.5A/230Vac |
| Inrush Current |
30A/115Vac 60A/230Vac, cold start |
| Leakage Current |
<1.5mA / 240Vac |
| Set Up, Rise Time |
1000ms, 50ms at full load |
| Hold Time |
16ms at full load |
| Over Load Protection |
105 ~ 150% rated output power. Protection type : Hiccup mode, recovers automatically after fault co |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Over Temperature Protection |
RTH2 >70°C ±10°C Detect on RTH2 thermistor |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Working Temperature |
-10°C to +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature., Humidity |
-20°C to +85°C , 10 ~ 95% RH |
| Temperature Coefficient |
±0.05%/°C (0 ~ 45°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV E60950-1, EN60335, EN60335-1, EN60335-2-29 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3, |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
| MTBF |
249.5K hrs min. MIL-HDBK-217F (25?C ) |