General Specifications
| Input Voltage |
90 ~ 264Vac; 120 ~ 370Vdc |
| Input Frequency |
47-440Hz |
| Input Current |
1A/112Vac 0.7A/230Vac |
| Inrush Current |
15A/ 115Vac, 30A/ 230Vac |
| Leakage Current |
<0.75mA |
| Output Power |
Rated output power for convection; 52W with 18CFM min. Forced air |
| Set Up, Rise Time |
800mS, 20mS at full load |
| Hold Up Time |
60mS at full load |
| Over Load Protection |
53 ~ 75W rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed. |
| Working Temperature |
-10°C to +60°C (Refer to derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C to +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.04%/°C (0~50°C) on +5V output |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KV, I/P-FG:1.5KV,O/P-FG:0.5KV, 1min. |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standard |
UL60950, TUV EN60950-1 |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, Criteria A |
|