Q-250B - Q-250D
Home > Products > Q-250 Series 250W Quad Output AC-DC Enclosed Switching Power Su > Q-250D
|
Standards
|
General Specifications
| SETUP, RISE, HOLD TIME |
800ms, 50ms, 20ms at full load |
| VOLTAGE RANGE |
90 ~ 132VAC / 176 ~ 264VAC Selected by switch 248 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| AC CURRENT |
6A/115VAC 3.5A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 50A |
| LEAKAGE CURRENT |
<2mA / 240VAC |
| OVER LOAD |
105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault cond |
| OVER VOLTAGE |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| WORKING TEMP. |
-10 ~ +60?C (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85?C , 10 ~ 95% RH |
| TEMP. COEFFICIENT |
?0.03%/?C (0 ~ 50?C) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY STANDARDS |
UL60950 Approved |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| MTBF |
219.5K hrs min. MIL-HDBK-217F (25?C) |
|
Q-250B
|
DC Voltage
|
Rated Current
|
Current Range
|
Rated Power
|
Ripple & Noise
|
Voltage Tolerance
|
Line Regulation
|
Load Regulation
|
Efficiency
|
|
+5V
|
20A
|
2-20A
|
201W
|
80mVp-p
|
±2.0%
|
±0.5%
|
±1.0%
|
73%
|
|
+12V
|
7A
|
0.5-7A
|
201W
|
120mVp-p
|
+8,-10%
|
±1.0%
|
±6.0%
|
73%
|
|
-12V
|
1A
|
0.5-1A
|
201W
|
120mVp-p
|
±10%
|
±1.0%
|
±8.0%
|
73%
|
|
-5V
|
1A
|
0-1A
|
201W
|
50mVp-p
|
±6.0%
|
±1.0%
|
±2.0%
|
73%
|
|
 |
| Add this product to your ClipBook |