S-250-5 - S-250-5
Home > Products > S-250 Series 250W Single Output AC-DC Enclosed Switching Power > S-250-5
|
Standards
|
General Specifications
| SETUP, RISE, HOLD TIME |
800ms, 50ms, 16ms at full load |
| VOLTAGE RANGE |
90 ~ 132VAC / 176 ~ 264VAC Selected by switch 248~370VDC |
| FREQUENCY RANGE |
47~ 63Hz |
| AC CURRENT |
6A/115VAC 3.5A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 50A/230VAC |
| LEAKAGE CURRENT |
<2mA / 240VAC |
| OVER LOAD |
105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault cond |
| OVER VOLTAGE |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| WORKING TEMP. |
-10 ~ +60?C (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85?C , 10 ~ 95% RH |
| TEMP. COEFFICIENT |
?0.03%/?C (0 ~ 50?C) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY STANDARDS |
UL60950 Approved |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| MTBF |
238.9K hrs min. MIL-HDBK-217F (25?C) |
|
S-250-5
|
DC Voltage
|
Rated Current
|
Current Range
|
Rated Power
|
Ripple & Noise
|
Voltage ADJ Range
|
Voltage Tolerance
|
Line Regulation
|
Load Regulation
|
Efficiency
|
Over Voltage
|
|
5V
|
40A
|
0-40A
|
200W
|
80mVp-p
|
4.75-5.5V
|
±2.0%
|
±0.5%
|
±1.0%
|
74%
|
5.75-6.75V
|
|
 |
| Add this product to your ClipBook |