S1500-248E3-UK-1 - 1500W 48V 40A I/P to 220V O/P True Sine Inverter
Home > Products > S1500 Series 1 1500Watt DC-AC True Sine Wave Inverter > 1500W 48V 40A I/P to 220V O/P True Sine Inverter
|
Standards
|
General Specifications
| INPUT |
|
| No load current draw |
≤12W non saving mode, ≤1.5W saving mode |
| OUTPUT |
|
| AC Rated Voltage |
220V |
| AC Voltage |
220/230/240 selectable by DIP switch |
| Rated Power |
1500 Watts |
| Surge Power |
2000 Watts |
| Waveform |
True sine wave (THD <3%) |
| Frequency |
50Hz±0.1% |
| AC Regulation |
-10 to +4% |
| Power Saving Recovery |
5 seconds |
| LED Indicators |
OVP, UVP, OTP, OLP nad Saving mode status |
| Over Load Protection |
>1700W shutdown o/p voltage, re-power on to recover |
| Over Temperature Protection |
85°C ±5°C / 185±40°F, Reset: re-power on |
| Output Short |
Shut-off, Reset: re-power on |
| Battery Polarity |
By fuse open |
| Operating Temperature |
0°C to 40°C |
| Operating Humidity |
20%~90% RH non-condensing |
| Storage Temperature, Humidity |
-30°C to 70°C / -22~+158°F, 10~95% RH |
| Temperature Coefficient |
±0.05%/°C (0~50°C) |
| Isolation Resistance |
I/P-O/P:100M Ohms / 500VDC |
| Safety & EMC |
Compliance to EN55022 Class B, 72/245/CEE, 95/54/CE |
|
EN61000-4-2,3, ENV50204, EN60950 |
| MTBF |
50K hrs minimum MIL-HDBK-217F (25°C) |
| Cooling |
By fan, >600W fan ON: <500W fan OFF |
|
S1500-224E3-UK Input Data
|
Part No
|
DC Current
|
DC Voltage
|
Voltage Range
|
Eff.
|
Fuse
|
Bat. Low Alarm
|
Bat. Low Shutdown
|
Over Voltage
|
|
S1500-248E3-UK
|
40A
|
48V
|
42~62Vdc
|
90%
|
10A*6
|
42±2V
|
40±2V
|
62~64V
|
|
(360KB)
|
| Add this product to your ClipBook |