| Input Voltage |
180 ~ 260Vac 260 ~ 370Vdc see the derating curve |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
>0.98 / 230Vac |
| AC Current |
5.0A/ 230Vac |
| Inrush Current |
60A/ 230Vac |
| Leakage Current |
3.5mA/ 240Vac |
| Set Up, Rise, Hold Up Time |
800ms, 400ms, 12ms at full load |
| Voltage Adjustment Range |
3.0%Typical adjustment by potentiometer 20% ~ 100% adjustment by 1 ~ 5VDC external control |
| Over Load Protection |
105~115% rated output power |
|
Current limiting, delay shut down o/p voltage, re-power on to recover |
| Over Voltage Protection |
110 ~ 135% Follow to output set up point |
|
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
>100°C/ measure by heat sink, near transformer |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Working Temperature |
-20°C ~ +65°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C 10 ~ 95% RH |
| Temperature Coefficient |
0.04% /°C (0 ~ 50°C) |
| Vibration |
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC/ 25/°C 70% RH |
| Safety Standards |
UL60950, TUV EN60950-1 approved |
| EMC |
Compliance to EN55022 (CISPR22) class A; EN61000-3-2,3; |
|
EN61000-4-2,3,4,5,6,8,11, light industry level, criteriaA |
| Power Good Signal |
Open collector of NPN transistor |
| Special Function |
DC Voltage Adj., remote sensing, remote control, parallel operation |
|
(refer to control terminal instruction manual) |
| Cooling |
By fan, >20% load or >50°C fan on |
| MTBF |
74.9K hrs min. MIL-HDBK-217F (25°C) |