PS-05 are new members to our open frame product line, designed to fill up the gap of lower wattage units. Complying with worldwide safety and performance standards they bear CB and CE marks. Featuring short circuit, over load, over voltage and over temperature protections these small gadgets securely provide the power source to your system within an economical budget.
| Input Voltage | 85 ~ 264Vac 120 ~ 370Vdc |
|---|---|
| Input Frequency | 47 ~ 63Hz |
| Input Current | 0.15A at 115Vac 0.07A at 230Vac |
| Inrush Current | 30A at 230Vac, cold start |
| Leakage Current | <0.5mA at 240VAC |
| Setup, Rise Time | 1000ms, 20ms |
| Hold Time | 100ms at full load |
| Over Load Protection | Above 105% rated output power |
| Hiccup mode, recovers automatically after fault condition is removed | |
| Over Temperature Protection | Tj 140°C typically (U1) Detect on main control IC |
| Hiccup mode, recovers automatically after fault condition is removed | |
| Working Temperatire | -10°C to +60°C (refer to output load derating curve) |
| Working Humidity | 20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity | -20°C to +85°C, 10~95% RH |
| Temp. Coefficient | ±0.05%/°C (0~50°C) |
| Vibration | 10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X,Y,Z axes |
| Withstand Voltage | I/P-O/P:3KVAC |
| Isolation Resistance | I/P-O/P:100M Ohms/500Vdc |
| Safety Standards | EN60950-1 CB Approved by TUV |
| EMC | Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3 |
| EN61000-4-2,3,4,5,6,8,11 light industry level, criteria A |