Features- Universal AC input
- 3 pole AC inlet IEC320-C14
- Built-in active PFC function, PF>0.95
- Class I power (with earth pin)
- Short circuit, over load, over voltage, ver temperature protections
- Fully enclosed plastic case
- No load power consumption < 1W @240VAC
Applications- POS system
- Home multi-media system
- Industrial PC based equipment
DescriptionATX-100, a fanless ATX power in a desktop adapter style plastic enclosure, is rated for 100W continuous power and possesses the capability of 125W or 150W peak load for short periods. With built in active PFC function ATX-100 can fulfill the requirements of harmonic current as per EN-61000-3-2 with no load power consumption of <1W.
|
Standards

|
|
Specification
| Input Voltage |
90 ~ 264Vac 127 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF>0.95 at full load |
| Efficiency |
80% |
| Input Current |
1.4A/115Vac 0.7A/230Vac |
| Inrush Current |
< 60A at 230Vac, cold start |
| Leakage Current |
<2mA/ 240VAC |
| Set Up, Rise Time |
3000ms, 80ms at full load |
| Hold Up Time |
16ms at full load |
| Rated Power |
100W |
| Over Load Protection |
Shut down o/p voltage (except 5VSB), re-power on to recover |
| Over Voltage Protection |
Shut down o/p voltage (except 5VSB), re-power on to recover |
| Over Temperature Protection |
105°C ±5°C (TSW1: detect on heatsink of power transistor) |
|
Shut down o/p voltage (except 5VSB), re-power on to recover |
| Power OK |
TheTTLcompatible signal out with 100 ~ 500ms delay after set up |
| PS-ON |
Power ON:PS-ON= |
| Working Temperature |
0°C ~ +50°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.05%/°C (0 ~ 60°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min.each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC |
| Isolation Resistance |
I/P-O/P:>100M Ohms/500VDC 25°C 70%RH |
| Safety Standards |
Design refer to UL60950-1, TUV EN60950-1 |
| EMC |
Compliance to EN55022 (CISPR22) Class B, EN61204-3; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A |
| MTBF |
152Khrs min. MIL-HDBK-217F (25°C) |
|
Items
ATX-100 Output Data
|
Part Code
|
Voltage
|
Rated Current
|
Current Range
|
R&N
|
Tol.
|
Line Reg.
|
Load Reg.
|
OLP
|
OVP
|
|
ATX-100
|
3.3V
|
5A
|
0 ~ 6A
|
100mV
|
±5.0%
|
±1.0%
|
±5.0%
|
6.2A min.
|
3.7 ~ 4.1V
|
|
|
5V
|
6A
|
0 ~ 8A
|
100mV
|
±5.0%
|
±1.0%
|
±5.0%
|
8.2A min.
|
5.7 ~ 6.5V
|
|
|
12V
|
3.75A
|
1 ~ 7A
|
120mV
|
±5.0%
|
±1.0%
|
±5.0%
|
7.2A min.
|
13.2 ~ 14.4V
|
|
|
-12V
|
0.3A
|
0 ~ 0.5A
|
120mV
|
±10.0%
|
±1.0%
|
±10.0%
|
---
|
---
|
|
|
5Vsb
|
1A
|
0 ~ 2A
|
100mV
|
±5.0%
|
±1.0%
|
±5.0%
|
---
|
---
|
|
(343KB)
|