Specification
| VOLTAGE ADJ. RANGE |
CH1: +10,-5% |
| SETUP, RISE, HOLD TIME |
800s, 20ms, 60ms/230VAC 1.6s, 20ms, 12ms/115VAC at full load |
| VOLTAGE RANGE |
88 ~ 132VAC/176 ~ 264VAC selected by switch 240 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| AC CURRENT |
2.5A/115VAC 1.25A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 35A |
| LEAKAGE CURRENT |
<3.5mA / 240VAC |
| OVER LOAD |
105 ~ 135% of rate load |
|
Protection type : Shut down o/p voltage, re-power on to recover |
| OVER VOLTAGE |
CH1:5.75 ~ 6.75VDC
Protection type : Shut down o/p voltage, re-power on to recover |
| WORKING TEMP., HUMIDITY |
-10 ~ +60?C (Refer to output load derating curve), 20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85?C , 10 ~ 95% RH |
| TEMP. COEFFICIENT |
?0.03%/ ?C(0~50?C ) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY STANDARDS |
UL60950-1, TUV EN60950 Approved |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
| HARMONIC CURRENT |
Compliance to EN61000-3-2,-3, Class A |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| MTBF |
274.5K hrs min. MIL-HDBK-217F (25?C ) |
| DIMENSIONS |
199*110*50mm (L*W*H) |
|
Items
T-120 Series
|
Part No
|
Output
|
Tol.
|
R&N
|
Eff.
|
|
T-120A
|
5V, 11A
|
±2.0%
|
80mV
|
77%
|
|
|
12V, 5A
|
±6.0%
|
120mV
|
77%
|
|
|
-5V, 1A
|
±6.0%
|
80mV
|
77%
|
|
T-120B
|
5V, 11A
|
±2.0%
|
80mV
|
77%
|
|
|
12V, 4A
|
±6.0%
|
120mV
|
77%
|
|
|
-12V, 1A
|
±6.0%
|
120mV
|
77%
|
|
T-120C
|
5V, 10A
|
±2.0%
|
80mV
|
76%
|
|
|
15V, 3.5A
|
±10.0%,-5%
|
150mV
|
76%
|
|
|
-15V, 1A
|
±10.0%,-5%
|
150mV
|
76%
|
|
T-120D
|
5V, 8A
|
±2.0%
|
80mV
|
80%
|
|
|
12V, 2A
|
±6.0%
|
120mV
|
80%
|
|
|
24V, 2A
|
±6.0%
|
180mV
|
80%
|
|