| Input Voltage |
100VAC to 240VAC, ±10% full range |
| Input Frequency |
47Hz to 63Hz |
| Input Current |
1A at 115VAC or 0.5A at 230VAC, maximum |
| Inrush Current |
<30A at 115VAC input or 60A at 230VAC input at full load, cold start, and 25°C. |
| No Load Input Power |
<0.5W |
| Leakage Current |
0.75mA maximum |
| Dynamic Load Regulation |
±5% excursion for 50%-100% or 100%-50% load change up to 1KHz (duty 50%) |
| Hold Up Time |
>8.3mS at full load, nominal line |
| Rise Time |
50mS maximum |
| Over Voltage Protection |
105 ~ 135% rated output voltage |
|
Clamp by zener diode, output short |
| Short Circuit Protection |
<3A typically |
|
Hiccup mode, auto recover when fault is removed |
| Over Load Protection |
110 ~ 200% rated output power |
| Stability |
2% max at constant load, after 30 mins. of operation |
| Operating Temperature |
0°C to 50°C (refer to derating curve) |
| Operating Humidity |
20% to 90% RH non condensing |
| Storage Temperature |
-20°C to +85°C |
| Storage Humidity |
10% to 95% RH |
| Temperature Coefficient |
±0.03% /°C (0~50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, for 60min. each along X, Y, Z axes |
| Safety Standards |
UL60950-1, CSA C22.2, TUV EN60950-1, CB, PSE, LPS & CE Approved |
| EMC |
Compliance to EN55022 class B, FCC PART 15 / CISPR22 Class B, |
|
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A |
| Withstand Voltage |
I/P-O/P:3KVAC , I/P-FG:1.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG:100M Ohms / 500VDC |
| MTBF |
500Khrs min. MIL-HDBK-217F(25°C) |
| DC Connector |
2.5 x 5.5x x 9.5mm tuning fork type, centre positive |