.jpg)
TS-200 Series are high performance DC/AC power inverters released to cover lower wattage applications. Using high frequency circuit topology this true sine wave inverter has efficiency up to 88%. Capabile of providing 200W continously as well as a peak load of 230W for 180 seconds, 300W for 10 seconds or 400W surge power for 30 utility cycles. The output AC voltage and frequency of TS-200 can be easily adjusted via the front panel. TS-200 is suitable for powering all kinds of home appliances, power tools, and office & portable equipment in vehicles, yachts, mobile homes or places that the utility can’t be reached or the power quality is poor.
Samples available Q4 2009
Safety Aprovals Q4 2009
| Rated Power | 200W |
|---|---|
| Maximum Output Power | 230W for 180 sec. / 300W for 10 sec./ surge power 400W for 30 cycles |
| AC Voltage | Factory setting set at 110VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W |
| Factory setting set at 230VAC 200 / 220 / 230 / 240VAC selectable by setting button S.W | |
| Output Frequency | 110VAC 60±0.1Hz 50/60Hz selectable by setting button |
| 230VAC 50±0.1Hz 50/60Hz selectable by setting button | |
| Waveform | True sine wave (THD<3%) at rated input voltage |
| AC Regulation | ±3.0% |
| Front Panel Indicator | Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal |
| Input Off Mode Current Draw | <1mA |
| Battery Types | Open & sealed Lead Acid |
| Battery Polarity | By internal fuse open |
| Over Temperature Protection | Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power MOSFET |
| Output Short Protection | Shut down o/p voltage, re-power on to recover |
| Over Load Protection | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. |
| Shut down o/p voltage, re-power on to recover | |
| GFCI Protection | Optional on 110VAC models, Type F only |
| Working Temperature | 110VAC models -10°C ~ +35°C @ 100% load ; +60°C @ 50% load |
| 230VAC -10°C ~ +40°C full load, +60°C 50% load | |
| Working Humidity | 20% ~ 90% RH non-condensing |
| Storage Temperature, Humidity | -30°C ~ +70°C/ -22 ~ +158°F, 10 ~ 95% RH |
| Vibration | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | 110VAC model design refers toUL458 |
| LVD | 230VAC model refers to EN60950-1 |
| Withstand Voltage | Bat I/P-AC O/P:3.0KVAC AC O/P- FG:1.5KVAC |
| Isolation Resistance | Bat I/P-AC O/P,AC O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH |
| EMC | 110VAC models comply to FCC class A |
| 230VAC models comply to EN55022 classA, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EN61000-4-2,3,8 ENV50204 | |
| Dimensions | 205 x 158 x 59mm |
| Part Number | Voltage (max/rated) | Power (watts) | Efficiency (%) |
|---|---|---|---|
| TS-200-112-D | 110V | 200W | 86% |
| TS-200-124-D | 110V | 200W | 88% |
| TS-200-148-D | 110V | 200W | 88% |
| TS-200-212-D | 230V | 200W | 86% |
| TS-200-224-D | 230V | 200W | 88% |
| TS-200-248-D | 230V | 200W | 88% |
TS-200 Series Specifications
| Part No | Input Battery Voltage | Input Voltage Range | Input DC Current | No Load Power Draw | Eff. | Battery Input Protection Fuse | Bat. Low Alarm | Bat. Low Shutdown | OTP |
|---|---|---|---|---|---|---|---|---|---|
| TS-200-112-D | 12V | 10.5 ~ 15VDC | 20A | 1.25A | 86% | 30A*2 | 11.3±4% | 10.5±4% | 85°C ±5°C |
| TS-200-124-D | 24V | 21 ~ 30VDC | 10A | 0.63A | 87.5% | 30A*1 | 22.5±4% | 21±4% | 80°C ±5°C |
| TS-200-148-D | 48V | 42 ~ 60VDC | 5A | 0.32A | 88% | 15A*1 | 45±4% | 42±4% | 80°C ±5°C |
| TS-200-212-D | 12V | 10.5 ~ 15VDC | 20A | 1.25A | 86% | 30A*2 | 11.3±4% | 10.5±4% | 85°C ±5°C |
| TS-200-224-D | 24V | 21 ~ 30VDC | 10A | 0.63A | 87.5% | 30A*1 | 22.5±4% | 21±4% | 80°C ±5°C |
| TS-200-248-D | 48V | 42 ~ 60VDC | 5A | 0.62A | 88% | 15A*1 | 45±4% | 42±4% | 80°C ±5°C |