| OUTPUT |
|
| Rated Power |
400W |
| Maximum Output Power |
460W for 180 sec. / 600W for 10 sec./ surge power 800W for 30 cycles |
| Output AC Voltage |
Factory setting set at 110VAC - 100 / 110 / 115 / 120VAC selectable by setting button S.W |
|
Factory setting set at 230VAC - 200 / 220 / 230 / 240VAC selectable by setting button S.W |
| Frequency |
110VAC models 60±0.1Hz 50/60Hz selectable by setting button |
|
230VAC models 50±0.1Hz 50/60Hz selectable by setting button |
| Waveform |
True sine wave (THD<3%) at rated input voltage |
| AC Reguation |
±3.0% |
| Front Panel Indicator |
Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal |
| Over Temperature Protection |
Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power MOSFET |
| Output Short Protection |
Shut down o/p voltage, re-power on to recover |
| Over Load Protection |
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. |
|
Shut down o/p voltage, re-power on to recover |
| GFCI Protection |
Optional on 110VAC models (Only type F) |
| *************************** |
|
| INPUT |
|
| Off Mode Current Draw |
<1mA |
| Battery Types |
Open & sealed LeadAcid |
| Input Battery Polarity Protection |
By internal fuse open |
| *************************** |
|
| Working Temperature |
-10°C ~ +40°C @ 100% load ; +60°C @ 50% load |
| Working Humidity |
20% ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-30°C ~ +70°C / -22°F ~ +158°F, 10 ~ 95% RH |
| Vibration |
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards |
110VAC models design refer toUL458 |
| LVD |
230VAC models meets EN60950-1 |
| Withstand Voltage |
Bat I/P-AC O/P:3.0KVAC AC O/P- FG:1.5KVAC |
| Isolation Resistance |
Bat I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH |
| EMC |
110VAC models compliance to FCC class A |
|
230VAC models compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark; |
|
EN61000-4-2,3,8 ENV50204 |
| Dimensions |
205 x 158 x 67mm |