MEAN WELL Products

HomeMEAN WELL ProductsDC/AC Power InvertersTS-400 Series 400W True Sine Wave DC/AC Power Inverter

TS-400 Series - TS-400 Series 400W True Sine Wave DC/AC Power Inverter

400W True Sine Wave DC/AC Power Inverter

Email
SKU: TS-400 Series Category:

Description

TS-400 Series are high performance DC/AC power inverters released to cover lower wattage applications. Using high-frequency circuit topology this true sine wave inverter has efficiency up to 88.5%. Capable of providing 400W continuously as well as a peak load of 460W for 180 seconds, 600W for 10 seconds or 800W surge power for 30 utility cycles. The output AC voltage and frequency of TS-400 can be easily adjusted via the front panel. TS-400 is suitable for powering all kinds of home appliances, power tools, and office & portable equipment in vehicles, yachts, mobile homes or places that the utility can’t be reached or the power quality is poor.

Additional information

Standards

CE

Type

DC/AC,Power Inverter,True Sine Wave

Range Power

Outputs

Single

OUTPUT
Rated Power 400W
Maximum Output Power 460W for 180 sec. / 600W for 10 sec./ surge power 800W for 30 cycles
Output AC Voltage Factory setting set at 110VAC – 100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 230VAC – 200 / 220 / 230 / 240VAC selectable by setting button S.W
Frequency 110VAC models 60±0.1Hz 50/60Hz selectable by setting button
230VAC models 50±0.1Hz 50/60Hz selectable by setting button
Waveform True sine wave (THD<3%) at rated input voltage
AC Reguation ±3.0%
Front Panel Indicator Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
Over Temperature Protection Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power MOSFET
Output Short Protection Shut down o/p voltage, re-power on to recover
Over Load Protection 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Shut down o/p voltage, re-power on to recover
GFCI Protection Optional on 110VAC models (Only type F)
***************************
INPUT
Off Mode Current Draw <1mA
Battery Types Open & sealed LeadAcid
Input Battery Polarity Protection By internal fuse open
***************************
Working Temperature -10°C ~ +40°C @ 100% load ; +60°C @ 50% load
Working Humidity 20% ~ 90% RH non-condensing
Storage Temperature, Humidity -30°C ~ +70°C / -22°F ~ +158°F, 10 ~ 95% RH
Vibration 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Safety Standards 110VAC models design refer toUL458
LVD 230VAC models meets EN60950-1
Withstand Voltage Bat I/P-AC O/P:3.0KVAC AC O/P- FG:1.5KVAC
Isolation Resistance Bat I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC 110VAC models compliance to FCC class A
230VAC models compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark;
EN61000-4-2,3,8 ENV50204
Dimensions 205 x 158 x 67mm
  • CE