| Input Voltage |
85 ~ 264Vac; 120 ~ 370Vdc |
| Input Fequency |
47 ~ 63Hz |
| Input Current |
1.2A/115Vac 0.7A/230Vac |
| Inrush Current |
20A/115Vac 40A/ 230Vac, Cold start |
| Leakage Current |
<3.5mA/240Vac |
| Voltage Adjustment |
4.75 ~ 5.5V on Output 1 |
| Set Up, Rise Time |
800ms, 50ms/230Vac 1600ms, 50ms/115Vac at full load |
| Hold Up Time |
70ms/230Vac 16ms/115Vac at full load |
| Over Load Protection |
105 ~ 150%/115VAC rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
5.75 ~ 6.75V Output 1 |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Working Temperature |
-10°C ~ +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10 ~ 95% RH |
| Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) on +5V output |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
CSA60950-1, (UL60950-1, IEC60950-1, TUV EN60950-1) Approved |
| EMC Standards |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3; ENV50204, |
|
EN61000-4-2,3,4,5,6,8,11; EN55024, Light industry level, criteria A |
| MTBF |
305.6K hrs min. MIL-HDBK-217F (25°C) |
| Dimensions |
129 x 98 x 38mm |
| Connection |
7P/ 8.25mm pitch terminal block |