SD-500H Series - 500W 96V Input Single Output DC-DC Converter
Home > Products > 500W 96V Input Single Output DC-DC Converter
Features- DC input active surge current limiting
- Wide 4:1 ~ 2:1 DC input range 96V: 72~144VDC
- Short circuit, over load, over voltage, over temperature, input polarity (by fuse) protections
- 2000VAC I/O Isolation
- Forced air cooling by built-in DC fan
- Output OK Signal
- Built-in remote ON-OFF control
- Built-in remote sense function
Applications- General electrical engineering
- Automotive
- Battery back-up
DescriptionA compact 500W single output DC-DC Converter with 72~144VDC input and output level options of 12V, 24V and 48V. With built-in short circuit, over load, over voltage, over temperature and input polarity protections this range also includes functions such as output OK signal, remote ON/OFF control and remote sense function.
|
Standards

|
|
Specification
| Input Voltage |
72 ~ 144VDC |
| Input Current |
6A/96VDC |
| Input Current at No Load |
0.1A/96VDC |
| Inrush Current |
60A/96VDC |
| Set Up, Rise Time |
500ms, 50ms at full load |
| Over Load Protection |
105 ~ 125% rated output power |
|
Constant current limiting shutdown o/p voltage, after about 5 sec., re-power on to recover |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
85°C ±10°C (TSW2) detect on heatsink of O/P diode; |
|
80°C ±5°C(TSW1)detect on heatsink of power transistor |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Remote On/Off Control |
Please refer to pdf |
| Output OK Signal |
Open collector signal low when PSU turns on, Max sink current: 10mA |
| Working Temperature |
-20°C ~ +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-40°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.02%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:2KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 25°C 70% RH |
| Safety Standards |
IEC60950-1 CB approved by TUV |
| EMC |
Compliance to EN55022 (CISPR22) Class B; |
|
EN61000-4-2,3,4,6,8; ENV50204, light industry level, criteria A |
| MTBF |
196.3K hrs min. MIL-HDBK-217 (25°C) |
|
Items
SD-500H Series Output Data
|
Part No
|
Voltage
|
Rated Current
|
Current Range
|
Rated Pwr
|
R&N
|
Volt. Adj.
|
Tol.
|
Line Reg.
|
Load Reg.
|
Eff.
|
OVP
|
|
SD-500H-12
|
12V
|
40A
|
0 ~ 40A
|
480W
|
150mV
|
11 ~ 15V
|
±1.0%
|
±0.5%
|
±0.5%
|
86%
|
16 ~ 19V
|
|
SD-500H-24
|
24V
|
21A
|
0 ~ 21A
|
504W
|
150mV
|
23 ~ 30V
|
±1.0%
|
±0.5%
|
±0.5%
|
89%
|
30.8 ~ 35.2V
|
|
SD-500H-48
|
48V
|
10.5A
|
0 ~ 10.5A
|
504W
|
150mV
|
46 ~ 60V
|
±1.0%
|
±0.5%
|
±0.5%
|
90%
|
62 ~ 68V
|
|
|