| Input Voltage |
88 ~ 264Vac 125 ~ 373Vdc (Withstand 300VAC surge for 5sec. Without damage) |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
1.3A/115Vac 0.8A/230Vac |
| Inrush Current |
36A/230Vac cold start |
| Leakage Current |
<2mA/ 240Vac |
| Set Up, Rise Time |
500ms, 20ms/230Vac 1200ms, 30ms/115Vac at full load |
| Hold Up Time |
60ms/230Vac 10ms/115Vac at full load |
| Over Load Protection |
110 ~ 150% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
5.75 ~ 6.75V on first output |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Working Temperature |
-25°C ~ +70°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-40°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50)°C on +5V output |
| Vibration |
10 ~ 500Hz, 5G 10min./1cycle, period for60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH |
| Safety Standards |
UL60950-1,TUV EN60950-1 approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; ENV50204; |
|
EN61000-4-2,3,4,5,6,8,11; EN61000-6-2 (EN50082-2), heavy industry level, criteria A |
| MTBF |
169.2Khrs min. MIL-HDBK-217F (25°C) |
| Dimensions |
99 x 97 x 36mm |