| Voltage range |
88 ~ 264VAC 124 ~ 370VDC |
| Frequency range |
47 ~ 63Hz |
| Power factor (typ.) |
0.95/230VAC 0.99/115VAC at full load |
| AC current (typ.) |
6.8A/115VAC 3.4A/230VAC |
| Inrush current (typ.) |
20A/115VAC 40A/230VAC |
| Leakage current |
<1.3mA / 240VAC |
| Line regulation |
±0.5% |
| Setup, rise time |
1500ms, 50ms at full load |
| Hold time (typ.) |
20ms at full load |
| Over load protection |
105 ~ 135% rated output power. |
|
Protection type:Constant current limiting, recovers automatically after fault condition is removed |
| Over voltage protection |
Protection type: Shut down o/p voltage, re-power on to recover |
| Over temperature protection |
5V:95°C(TSW1)Detect on heatsink of power transistor); 95°C(TSW51):Detect on heatsink of power diode) |
|
12V~48V:85°C(TSW1)Detect on heatsink of power transistor);80°C(TSW51): |
|
Detect on heatsink of power diode. Protection type:Shutdown o/p voltage, recovers automatically |
|
after temperature goes down, then re-power on to recover. |
| Remote control |
RC+/RC-: Short = Power on ; Open = Power off |
| POK signal |
PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V |
| Working temp. |
-20~+60°C (refer to output load derating curve) |
| Working humidity |
20 ~ 90% RH non-condensing |
| Storage temp., humidity |
-40~+85°C, 10~95% RH |
| Temp. coefficient |
±0.03%/°C (0~50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X,Y,Z axes |
| MTBF |
116.4K hrs min. MIL-HDBK-217F (25°C) |
| Safety standards |
UL60950-1, TUV EN60950-1 approved |
| Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI conduction & radiation |
Compliance to EN55022 (CISPR22) Class B |
| Harmonic current |
Compliance to EN61000-3-2,-3 |
| EMS immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A |