PLN-60 Series - 60W Single Output Class 2 Power Unit
Home > Products > 60W Single Output Class 2 Power Unit
Features- Universal AC input
- Fully isolated plastic case with IP64 level
- Built-in constant current limiting circuit with adjustable OCP level
- Short circuit, Over load, Over voltage, Over temperature Protections
- Built-in active PFC function
- IP64 design for indoor or outdoor installations
- UL1310,Class 2 power unit
- Cooling by free air convection
- 100% full load burn-in test
- High realibility
Applications- LED Lighting
- Moving Signs and Back Lighting
- Outdoor or Harsh Environment
DescriptionA 60W AC/DC enclosed type switching power supply with universal AC input and active PFC function. These limited power sources comply with UL1310 Class II that under any situation the output power will be less than 100VA to 5A. The high IP64 level design can protect the electronic components from dust and moisture damage and making it useable for indoor and outdoor applications.
Thanks to the simplified single stage PFC topology the required high power factor for the lighting industry can be achieved economically. Efficiencies are as high as 88% and hence can operate between -30°C and +70°C using only free air convection.
|
|
Specification
| Input Voltage |
90 ~ 264Vac |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF>0.9/230Vac PF>0.98/115Vac at full load |
| Input Current |
0.8A/115Vac 0.4A/230Vac |
| Inrush Current |
40A/230Vac |
| Leakage Current |
0.5mA/240Vac |
| O/P Current Adjustment Range |
3% ~ -25% |
| Voltage Tolerance |
±10% |
| Line Regulation |
±4.0% |
| Load Regulation |
±10% |
| Set Up, Rise Time |
1500ms, 100ms / 230Vac 3000ms, 100ms/115Vac at full load |
| Over Current Protection |
Constant current limiting, recovers automatically after fault condition is removed |
| Short Circuit Protection |
Hiccup mode, recovers automatically after fault condition is removed. |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
95°C ±10°C (TSW1) Detect on heatsink of power transistor |
| Working Temperature |
-30°C ~ +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RHnon-condensing |
| Storage Temperature, Humidity |
-40°C ~ +80°C 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X,Y, Z axes |
| Withstand Voltage |
I/P-O/P:4.25KVDC |
| Isolation Resistance |
I/P-O/P:100M Ohms/500VDC |
| Safety Standards |
UL1310 Class 2, CAN/CSAC22.2 No. 223-M91(except for 48V), IP64 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3 |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, Criteria A |
| MTBF |
497.8Khrs min. MIL-HDBK-217F (25°C) |
|
Items
PLN-60 Series Output Data
|
Part Code
|
Voltage
|
Rated Current
|
Current Range
|
Rated Pwr
|
R&N
|
Volt. Adj.
|
Eff.
|
OCP
|
OVP
|
|
PLN-60-12
|
12V
|
5A
|
0 ~ 5A
|
60W
|
2Vp-p
|
11 ~ 13V
|
84.5%
|
95 ~ 100%
|
13.8 ~ 16V
|
|
PLN-60-15
|
15V
|
4A
|
0 ~ 4A
|
60W
|
2.4Vp-p
|
13.8 ~ 16.2V
|
85%
|
130% (max)
|
17.5 ~ 21V
|
|
PLN-60-20
|
20V
|
3A
|
0 ~ 3A
|
60W
|
1.8Vp-p
|
18 ~ 22V
|
87%
|
130% (max)
|
22.8 ~ 25V
|
|
PLN-60-24
|
24V
|
2.5A
|
0 ~ 2.5A
|
60W
|
2.7Vp-p
|
22 ~ 26V
|
87%
|
130% (max)
|
28 ~ 32V
|
|
PLN-60-27
|
27V
|
2.3A
|
0 ~ 2.3A
|
62.1W
|
2.7Vp-p
|
25 ~ 30V
|
87%
|
130% (max)
|
31 ~ 35V
|
|
PLN-60-36
|
36V
|
1.7A
|
0 ~ 1.7A
|
61W
|
3.6Vp-p
|
32.5 ~ 39V
|
87.5%
|
130% (max)
|
41 ~ 46V
|
|
PLN-60-48
|
48V
|
1.3A
|
0 ~ 1.3A
|
62.5W
|
4.6Vp-p
|
43.6 ~ 51.8V
|
88%
|
130% (max)
|
54 ~ 60V
|
|
(168KB)
|