ELN-60 Series - 60W Single Output Class II Switching Power Supply
Home > Products > 60W Single Output Class II Switching Power Supply
Features- Universal AC input / Full range
- Fully isolated plastic case with IP64 level
- Built-in constant current limiting circuit with adjustable OCP level
- Short circuit, over load, over voltage protections
- IP64 design for indoor or outdoor installations
- Built-in dimming function : 1~10VDC or PWM controlled(Optional)
- UL1310,Class 2 power unit
- Cooling by free air convection
- 100% full load burn-in test
- Suitable for LED lighten and moving sign applications
- High realibility
Applications- LED Lighting
- Moving Sign
- Back Lighting
- Stage and Theatre Lighting
- Architectural Lighting
DescriptionELN-60 Series is a 60W AC/DC enclosed switching power supply targeting economical lighting applications. Of a non-PFC design, to keep costs low, the unit still complies with UL1310 Class 2 and the IP64 design ensures the components are protected from dust & moisture for application in harsher locations than most power supplies.
|
Standards
|
|
Specification
| Input Voltage |
90 ~ 264Vac |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
1.2A/115Vac 0.7A/230Vac |
| Inrush Current |
60A/230Vac, cold start |
| Leakage Current |
0.25mA/ 240Vac |
| Output Current Adjustment Range |
-25% ~ 3% |
| Output Voltage Tolerance |
±5.0% |
| Line Regulation |
±1.0% |
| Load Regulation |
±2.0% |
| Setup, Rise Time |
500ms, 30ms / 230Vac 1500ms, 30ms / 115Vac at full load |
| Hold Up Time |
50ms/230Vac 16ms/115Vac at full load |
| Over Current Protection |
95 ~ 110% for 9V & 12V 130% max. for 15V to 48V |
|
Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Diming Control Function |
1 ~ 10VDC or PWM (Optional Feature) |
| Working Temperature |
-20°C to +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-40°C to +80°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X,Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC |
| Isolation Resistance |
I/P-O/P:>100M Ohms/500VDC 25°C 70% RH |
| Safety Standards |
Design refers to UL1310 Class 2,TUV EN60950-1, EN61347-2-13; |
|
CAN/CSAC22.2 No. 223-M91(except for 48V), IP64 approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, Criteria A |
| MTBF |
603Khrs min. MIL-HDBK-217F (25°C) |
|
Items
ELN-60 Series Output Data
|
Part Code
|
Voltage
|
Rated Current
|
Current Range
|
Rated Pwr
|
R&N
|
Volt. Adj.
|
Eff.
|
OVP
|
|
ELN-60-9
|
9V
|
5A
|
0 ~ 5A
|
45W
|
120mV
|
8.7 ~ 10.5V
|
82%
|
11 ~ 13.5V
|
|
ELN-60-12
|
12V
|
5A
|
0 ~ 5A
|
60W
|
120mV
|
10.8 ~ 13.2V
|
85%
|
13.8 ~ 16V
|
|
ELN-60-15
|
15V
|
4A
|
0 ~ 4A
|
60W
|
150mV
|
13.5 ~ 16.5V
|
86%
|
17.5 ~ 21V
|
|
ELN-60-24
|
24V
|
2.5A
|
0 ~ 2.5A
|
60W
|
150mV
|
21.6 ~ 26.4V
|
87%
|
28 ~ 32V
|
|
ELN-60-27
|
27V
|
2.3A
|
0 ~ 2.3A
|
62.1W
|
200mV
|
24.3 ~ 29.7V
|
87%
|
31 ~ 35V
|
|
ELN-60-48
|
48V
|
1.3A
|
0 ~ 1.3A
|
62.5W
|
250mV
|
43.2 ~ 52.8V
|
88%
|
54 ~ 60V
|
|
(421KB)
|