Specification
| Input Voltage |
90 ~ 264Vac 127 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF> 0.90/230Vac |
| Input Current |
1.3A/100Vac |
| Inrush Current |
100A/240Vac |
| Leakage Current |
0.75mA/ 240Vac |
| Set Up, Rise, Hold Time |
300ms, 50ms , 10ms at full load |
| Over Load Protection |
110 ~ 150% rated output voltage |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
110 ~ 150% rated output voltage |
|
Clamp by zener diode |
| Working Temperature |
0°C to + 50°C (Refer to output load derating curve) |
| Working Humidity |
20% ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C to +85°C, 10 ~ 95% RH |
| Teperature Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 3AXES 10min./1cycle, period for 60min.each along X,Y, Z axes |
| Withstand Voltage |
I/P-O/P:1.5KVDC; I/P-FG: 1.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG: 100M ohms/500VDC/25°C/70% RH |
| Safety Standards |
UL60950-1,TUV EN60950-1, BSMI CNS14336 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B, FCC part 15 Class B, CNS13438 Class B |
|
EN61000-3-2,3; EN61000-4-2,3,4,5,6,8,11, Light industry level, Criteria A |
| MTBF |
30K hrs min. MIL-HDBK-217F (25°C) |
| DC Connector |
2.5 x 5.5 x 11mm, center positive, tuning fork type |
| DC Cable |
4ft UL1185 16 AWG cable |
|