Meanwell Products

HomeMeanwell ProductsDC/AC Power Inverters700W True Sine Wave DC-AC Power Inverter

TS-700 Series - 700W True Sine Wave DC-AC Power Inverter

Email

Description

TS-700 Series are high performance DC/AC power inverters released to cover lower wattage applications. Uising high frequency circuit topology this true sine wave inverter has efficiency up to 91%. Capabile of providing 700W continously as well as a peak load of 800W for 3 minutes, 1050W for 10 seconds or 1400W surge power for 30 utility cycles. The output AC voltage and frequency of TS-700 can be easily adjusted via the front panel, as can the standby saving mode function. TS-700 is suitable for powering all kinds of home appliances, power tools, and office & portable equipment in vehicles, yachts, mobile homes or places that the utility can’t be reached or the power quality is poor.

Additional information

Standards

CE, E13

Type

DC/AC

Outputs

Single

  • True sine wave output (THD<3%)
  • High surge power up to 1400W
  • High efficiency up to 91%
  • Power ON-OFF switch
  • Standby saving mode can be selectable
  • Front panel indicator for operation status
  • Built-in fan ON-OFF control function
  • Bat. low alarm / Bat. low shutdown / Over voltage / Over temp./ Output short / Reverse polarity / Overload protections
  • Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc.
  • Home appliances
  • Power tools
  • Office equipment
  • Portable equipment
  • in vehicles, yachts, mobile homes or places with unstable/unreliable utilities
OUTPUT
Rated Power700W
Max. Output Power800W for 180 sec. / 1050W for 10 sec./ surge power 1400W for 30 cycles
AC VoltageFactory setting set at 230VAC
200 / 220 / 230 / 240VAC selectable by setting button S.W
Frequency50±0.1Hz 50/60Hz selectable by setting button S.W
WaveformTrue sine wave (THD<3%) at rated input voltage
AC Regulation±3.0%
Saving ModeLoad <5W will be changed to standby mode
Front Panel IndicatorBattery voltage level, output load level, saving mode, fault and operation status
***************************
INPUT
No Load Dissipation<6W @ standby saving mode
Off Mode Current Draw<1mA
Battery TypesOpen & sealed Lead Acid
Input Bat. Polarity ProtectionBy internal fuse open
***************************
Over Temperature Protection75°C ±5°C
Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power diode
Output Short ProtectionShut down o/p voltage, re-power on to recover
Over Load Protection105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Shut down o/p voltage, re-power on to recover
GFCI ProtectionNone
Working Temperature0 ~ +40°C @ 100% load ; +60°C @ 50% load
Working Humidity20% ~ 90% RH non-condensing
Storage Temperature, Humidity-30°C ~ +70°C / -22 ~ +158°F, 10 ~ 95% RH
Vibration10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Safety StandardsEN60950-1
Withstand VoltageBat I/P-AC O/P: 3.0KVAC AC O/P- FG: 1.5KVAC
Isolation ResistanceBat I/P-AC O/P, Bat I/P-FG:100M Ohms / 500VDC / 25°C / 70% RH
EMI Conduction & RadiationCompliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
EMS ImmunityCompliance to EN61000-4-2,3,8 ENV50204
  • CE