| OUTPUT |
|
| Rated Power |
1500W |
| Maximum Output Power |
1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles |
| AC Voltage |
Factory setting set at 230VAC 200 / 220 / 230 / 240VAC selectable by setting button S.W |
| Frequency |
50±0.1%Hz 50/60Hz selectable by setting button S.W |
| Waveform |
True sine wave (THD<3%) at rated input voltage |
| AC Regulation |
±3.0% |
| Transfer Time |
t<10ms inverter <-> by pass |
| Saving Mode |
Load <5W will be changed to standby mode |
| Front Panel Indicator |
Battery voltage level, output load level, saving mode, fault and operation status |
| *************************** |
|
| INPUT |
|
| No Load Dissipation |
<18W @ standby saving mode |
| Off Mode Current Draw |
<1mA |
| Battery Types |
Open & sealed lead acid |
| Input Bat. Polarity Protection |
By internal fuse open |
| *************************** |
|
| Over Temperature Protection |
68°C ±5°C Shut down o/p voltage, re-power on to recover: |
|
by internal RTH3 detect on heatsink of power transistor |
| Output Short Protection |
Shut down o/p voltage, re-power on to recover |
| Over Load Protection |
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. |
|
Shut down o/p voltage, re-power on to recover |
| GFCI Protection |
None |
| Circuit Breaker |
10A |
| Working Temperature |
0°C ~ 40°C @ 100% load; 60°C @ 50% load |
| Working Humidity |
20% ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-30°C ~ +70°C/-22°F ~ +158°F, 10 ~ 95% RH |
| Vibration |
10 ~ 500Hz, 3G 10min./1 cycle, 60 min. each along X, Y, X axes |
| Withstand Voltage |
Bat I/P-AC I/P:3.0KVAC Bat I/P-AC O/P:3.0KVAC AC O/P- FG:1.5KVAC |
| Safety Standards |
EN60950-1 |
| EMI Conducted & Radiation |
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark |
| EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204 |
| Control Wiring |
RJ11 -RS232 (Option) |