LPP-100-24 - 100.8W 24V 4.2A PFC Open Frame Switching PSU
Home > Products > Open Frame Switching Power Supply > LPP-100 Series 100W Single Output PFC Function Open Frame PSU > 100.8W 24V 4.2A PFC Open Frame Switching PSU
General Specifications
| Input Voltage |
85 ~ 264Vac 120 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF>0.95/230Vac PF>0.98/115Vac at full load |
| Input Current |
1.7A/115Vac 0.75A/230Vac |
| Inrush Current |
30A/230Vac, cold start |
| Leakage Current |
<2mA/ 240Vac |
| Set Up, Rise Time |
600ms, 30ms/230Vac 1200ms, 30ms/115Vac at full load |
| Hold Time |
28ms/230Vac 28ms/115Vac at full load |
| Over Load Protection |
105 ~ 150% rated output power |
|
Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Working Temperature |
-10°C ~ +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.05%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1 cycle, Period for 60min.each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; ENV50204; |
|
EN61000-4-2,3,4,5,6,8,11; EN55024, Light industry level, criteria A |
| MTBF |
224.3Khrs min. MIL-HDBK-217F (25°C) |
LPP-100-24 Specifications
| Part Number |
Voltage (max/rated) | Current (amps) | Power (watts) | R&N (mV) | Efficiency (%) |
| LPP-100-24
|
24V
|
4.2A
|
101W
|
150mV
|
83%
|