MEAN WELL Products
PID-250 Series - 250W Isolated Dual Output PFC Function PSU
SKU: PID-250 Series
Categories: Open Frame Switching Power Supply, Switching Power Supply
Description
A 250W dual output product with isolated outputs and PFC function designed to be used as an open frame or enclosed product. These compact 90~264V switchmode power supplies with active PFC are ideal for 1U installations. The isolated design between CH1 and CH2 can significantly prevent noise sourcing of motor action from entering control circuits and hence secure accurate operation of the end equipment. Accompany with the optional L-Bracket and cover to provide more alternatives to system configuration or solve mounting constraint issues. Other standard functions include remote control for CH1 and short circuit, over load, over voltage and over temperature protections.
Additional information
Standards | CB, CE, CSUUS, PFC, TUV |
---|---|
Type | AC/DC |
Outputs | Dual |
- Universal AC input, full range
- Isolated output & GND for CH1, CH2
- Built-In active PFC function, >0.93
- Short circuit, over load, over voltage & over temperature protections
- Cooling by free air convection
- Remote control function for CH1
- Peak load 170% for 10 sec. (CH1)
- Optional case available
- Motor based machinery
- Automation
- Test equipment
- POS systems
- Franking Machines
- Banking Machines
Input Voltage | 90 ~ 264Vac; 127 ~ 370Vdc |
Input Frequency | 47 ~ 63Hz |
Power Factor | PF>0.93/230Vac PF>0.97/115Vac at full load |
Input Current | 3A/115Vac 1.5A/230Vac |
Inrush Current | 55A/230Vac, cold start |
Leakage Current | <3.5mA/240Vac |
Set Up, Rise Time | 2500ms, 60ms/115Vac 1200ms, 60ms/230Vac |
Hold Up Time | 30ms at full load |
Over Load Protection | CH1: 105 ~ 170%rated output power |
Normally work within 10 sec and then shut down, re-power on to recover; >180% rated power | |
or short circuit, constant current limiting within 10 sec and then shut down, re-power on to recover | |
Over Voltage Protection | Shut down o/p voltage, re-power on to recover for CH1; |
Hiccup mode, recovers automatically afer fault condition is removed for CH2.(by zener diode clamp) | |
Over Temperature Protection | 95°C ±5°C Detect on heatsink of power transistor |
Shut down o/p voltage, recovers automatically after temperature goes down | |
Remote Control | CN52 : Open=CH1 & CH2 power on ; Short = CH1 power off, CH2 power on. |
when CH2 is malfunction, CH1 will be shut down | |
Working Temperature | -20°C to +70°C (refer to output load derating curve) |
Working Humidity | 20 ~ 90% RH non-condensing |
Storage Temperature, Humidity | -20°C ~ +85°C, 10 ~ 95% RH |
Temperature Coefficient | ±0.05%/°C (0 ~ 50°C) |
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X,Y, Z axes |
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 25°C 70%RH |
Safety Standards | UL60950-1,TUV EN60950-1 Approved |
EMC | Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3 |
EN61000-4-2,3,4,5,6,8,11; ENV50204, Heavy industry level, criteria A | |
MTBF | 150.4Khrs min. MIL-HDBK-217F (25°C) |
Dimensions | 222x95x40mm open frame type, 250x105.4x53mm enclosed type |
- CB
- CE
- CSUUS
- PFC
- TUV
Products in this range
Part number | Power (watts) | Voltage (max/rated) | Current (amps) | R&N (mV) | Efficiency (%) | |
---|---|---|---|---|---|---|
PID-250A | 205W | 12V | 5A | 120mV | 84% | Request Quote |
PID-250B | 251W | 24V | 5A | 150mV | 87% | Request Quote |
PID-250C | 252W | 36V | 5A | 200mV | 87% | Request Quote |
PID-250D | 251W | 48V | 5A | 200mV | 87% | Request Quote |