MEAN WELL Products

HomeMEAN WELL ProductsOpen Frame Switching Power SupplyLPP-100 Series 100W Single Output PFC Function Open Frame PSU

LPP-100 Series - LPP-100 Series 100W Single Output PFC Function Open Frame PSU

LPP-100 is a 100W Single Output PFC Function Open Frame PSUSeries

Email

Additional information

Weight 0.51 kg
Inputs

85 ~ 264VAC

Standards

CSUUS

Type

AC/DC,Industrial,Open Frame

Range Power

Outputs

Single

warranty

  • Fix Switching frequency at PFC:67KHz PWM:134KHz 
  • 100% full load burn-in test
  • Cooling by free air convection
  • Protections: Short circuit / Overload / Over voltage 
  • Universal AC input 
  • Built-in active PFC function
  • Electronic instruments, equipment and apparatus 
  • Mechanical equipment 
  • Industrial control system
  • Industrial automation machinery 
Input Voltage 85 ~ 264Vac 120 ~ 370Vdc
Input Frequency 47 ~ 63Hz
Power Factor PF>0.95/230Vac PF>0.98/115Vac at full load
Input Current 1.7A/115Vac 0.75A/230Vac
Inrush Current 30A/230Vac, cold start
Leakage Current <2mA/ 240Vac
Set Up, Rise Time 600ms, 30ms/230Vac 1200ms, 30ms/115Vac at full load
Hold Time 28ms/230Vac 28ms/115Vac at full load
Over Load Protection 105 ~ 150% rated output power
Constant current limiting, recovers automatically after fault condition is removed
Over Voltage Protection Shut down o/p voltage, re-power on to recover
Working Temperature -10°C ~ +60°C (Refer to output load derating curve)
Working Humidity 20 ~ 90% RH non-condensing
Storage Temperature, Humidity -20°C ~ +85°C, 10 ~ 95% RH
Temperature Coefficient ±0.05%/°C (0 ~ 50°C)
Vibration 10 ~ 500Hz, 2G 10min./1 cycle, Period for 60min.each along X, Y, Z axes
Withstand Voltage I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Safety Standards UL60950-1, TUV EN60950-1 Approved
EMC Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; ENV50204;
EN61000-4-2,3,4,5,6,8,11; EN55024, Light industry level, criteria A
MTBF 224.3Khrs min. MIL-HDBK-217F (25°C)
  • CSUUS