MEAN WELL Products
MP450 Series - 450W Modular Power Power Supply
Description
Switching power supplies with a modular design that consists of 2 stages; Front end PFC and output modules. Using zero voltage switching technology to realize the power factor correction, the line input is rectified into high DC voltage by the front end PFC stage, and then the DC output modules will transfer the operating voltage into all kinds of DC output voltages from 1.6V to 53V. There are currently 75W, 150W, 300W single output modules and 100W dual output modules to fulfil all kinds of applications up to 14 isolated outputs. There are millions of combinations available for the modular series. You can configure the DC outputs needed to get the fastest solution for your power requirements with safety and EMC certificates. No more NRE/safety application charges and long periods of waiting for certificates to come through! This is a revolutionary standard power solution that fulfils your custom made request!
For use with;
MS-75 Series
MS-150 Series
Additional information
Standards | CB, CE, CSUUS, PFC, TUV |
---|---|
Type | AC/DC |
Outputs | Quintuple |
- Universal input voltage
- Uses ZVS technology to reduce power dissipation and improve efficiency
- Large range of output configurations available
- Remote control on each module
- Remote sense on MS-75, 150 & 300 modules
- Built in active PFC, PF>0.95
- Built in parallel function on MS-300
- Fan alarm function
- Forced air cooling
Input Voltage | 86 to 264Vac or 120 to 370Vdc |
Input Frequency | 47 to 63Hz |
Input Current | 6.3A at 115Vac; 3.2A at 230Vac |
Inrush Current | 25A at 115Vac; 40A at 230Vac, cold start |
Power Factor Correction | >0.95 at 230Vac; >0.98 at 115Vac; full load |
Efficiency | 83% typically |
Leakage Current | <1.5mA at 240Vac |
Output Power | 450W maximum |
Setup, Rise, Hold-Up Time | 1500ms, 50ms, 20ms at full load |
Over Load Protection | Constant Current limiting, recovers automatically once fault condition removed |
Over Temperature Protection | Thermal switch detect on the heatsink of power MOSFET |
Should the power supply reach excessive temperatures it shall shut down | |
and auto recover once temperature returns to operable levels | |
Fan Fail | The outputs shall shut down should the fan malfunction |
Remote Control | RC+/RC-: 0 to 0.8V or Short, Power on |
RC+/RC-: 4 to 12V or Open, Power Off | |
Remote Inhibit Control | RC+/RC-:0V~0.8V or OPEN, POWER ON |
RC+/RC-:4V~12V or OPEN, POWER OFF | |
Auxiliary Power | 12V at 0.1A (only for remote on/off) |
Withstand Voltage | I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, 1 minute |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100MW/500Vdc |
Operating Temperature | -20°C to +70°C (refer to de-rating curve) |
Operating Humidity | 20% to 90% RH Non-condensing |
Storage Temperature, Humidity | -40°C to +85°C, 10% to 95% RH |
Temperature Coefficient | ±0.03%/°C (0°C to 50°C) |
Vibration | 10 to 500Hz, 2G 10min./1 cycle, 60 min. each along X, Y, Z axes |
Safety Standards | UL60950-1, TUV EN60950-1, EN60601-1 approved |
EMC | Complies to EN55022 Class B, EN6100-3, -2,3, EN61000-4-2,3,4,5,6,8,11, |
ENV50204, EN55024, EN61000-6-1, EN61204-3 Light Industrial Level, Criteria A |
- CB
- CE
- CSUUS
- PFC
- TUV