MEAN WELL Products

HomeMEAN WELL ProductsEnclosed Switching Power Supply125W Dual Isolated Output Enclosed Power Supply

RID125 Series - 125W Dual Isolated Output Enclosed Power Supply

Email

Description

AC/DC switching power supplies that can provide 125W using air convection. The units can withstand 300VAC input surge for 5 seconds and 5G vibration that is suitable to be operated in harsh environment. Possessing 12V or 24V main output channel (CH1) with up to 180% of high peak load capability the isolated design between CH1 and CH2 can significantly prevent noise sourcing from the motor action from entering control circuits and hence secure the accurate operation of the end equipment. Other standard functions include short circuit, overload, and over voltage protections.

Additional information

Standards

CB, CE, CSUUS, TUV

Type

AC/DC

Outputs

Dual

  • Isolated output & GND for CH1,CH2
  • AC input range selectable by switch
  • Short circuit, over load, over voltage protections
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • High realibilit
  • Motor-based machinery
  • Automation equipment
  • Test equipment
  • POS systems
  • Franking machines
  • Banking machines
  • Printers/plotters
Input Voltage88 ~ 132Vac / 176 ~ 264Vac selected by switch 248 ~ 373Vdc (300Vac peak 5sec. No damage)
Input Frequency47 ~ 63Hz
Input Current3A/115Vac 2A/230Vac
Inrush Current40A/230Vac, cold start
Leakage Current<2mA/240Vac
Set Up, Rise Time500ms, 20ms/230Vac 1200ms, 30ms/115Vac at full load
Hold Up Time36ms/230Vac 30ms/115Vac at full load
Over Load Protection110 ~ 150% rated output power
Hiccup mode, recovers automatically after fault condition is removed
Over Voltage ProtectionHiccup mode, recovers automatically after fault condition is removed
Working Temperature-20°C ~ +70°C (Refer to output load derating curve)
Working Humidity20 ~ 90% RH non-condensing
Storage Temperature, Humidity-40°C ~ +85°C, 10 ~ 95% RH
Temperature Coefficient±0.03%/°C (0 ~ 50°C) on +5V output
Vibration10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X,Y, Z axes
Withstand VoltageI/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Safety StandardsUL60950-1, TUV EN60950-1 Approved
EMCCompliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; ENV50204;
EN61000-4-2,3,4,5,6,8,11; EN61000-6-2 (EN50082-2) heavy industry level, criteria A
MTBF218.2Khrs min. MIL-HDBK-217F (25°C)
  • CB
  • CE
  • CSUUS
  • TUV