MPT-200 Series - 200W Triple Output Medical Open Frame Power Supply

Description
MPT-200 Series are 200W PCB type switching power supplies with active PFC function. Complying with both medical and industrial agency standards these units can deliver their full rated output of 200W with 25CFM forced are or 140W with convection fooling for wither medical or industrial applications. Featuring only 180uA of leakage current at 264VAC, they can be equipped into non-patient contact medical equipment and still comply with Class B EMI regulations. Standard function sinclude short circuit, over load, over voltage and over temperature protections, PG/PF signal output, remote sense and remote ON/OFF control that covers most of the demands for typicall usages. Since the height is only 35.5mm the MPT-200 series are also suitable for 1U applications or other height constraint applications.
Additional information
Standards | CB, CE, CSUUS, PFC, MEDICAL, TUVMedical |
---|---|
Type | AC/DC |
Outputs | Triple |
- Universal AC input / Full range
- Built-in active PFC, PF>0.95@230VAC
- Low leakage current <180µA
- Free air convection for 140W and forced air convection for 200W
- Power good and fail signal output
- Built-in remote ON-OFF control & remote sense function
- Fixed switching frequency at 100KHz
- Compliance to UL2601-1 & TUV EN60601-1 medical standards
- Non-patient contact medical
- 1U
- General electronics
- Low Profile IT
Input Voltage | 90~264 VAC, 127~370VDC |
Input Frequency | 47~440Hz |
Power Factor | PF>0.95/230VAC PF>0.98/115VAC, full load |
AC Input Current | 3.5A at 115VAC, 60Hz or 1.6A at 230VAC, 60Hz full load |
Inrush Current | <25A at 115VAC or <40A at 230VAC Cold start |
Setup, Rise Time | 1000ms, 20ms / 230VAC at full load , 3000ms, 20ms / 115VAC at full load |
Hold-Up Time | 16ms / 230VAC at full load, 16ms / 115VAC at full load |
Leakage Current | <180µA at 264VAC for earth leakage |
<100µA at 264VAC for patient leakage | |
DC Output ADJ Range | -5% to +10% rated output, on first output |
Over Load Protection | 120~160% rated load |
Auto recovery once fault condition removed | |
Over Voltage Protection | 115%~135% rated load, on first output |
Over Temperature Protection | At 95°C. Will shut down and recover automatically after temperature goes down |
Power Good/Fail Signal | TTL logic high for power good and TTL low for power fail |
Remote Control | RC+/RC-:0 ~ 0.8V=power on; 4 ~ 10V=power off sink current<4~10mA |
Working Temperature | -20°C to 70°C (refer to derating curve) |
Working Humidity | 20~90% RH non-condensing |
Storage Temperature | -40°C to +85°C |
Storage Humidity | 10~90% RH |
Temperature Coefficient | ±0.04%/°C (0~50°C) full load |
Vibration | 2G 10Hz ~500Hz 10 min cycle |
Medical Safety Standards | UL60601-1, TUV EN60601-1 approved |
Commercial Safety Standards | Complies with UL60950-1, TUV EN60950-1 |
Withstand Voltage | I/P-O/P: 4000VAC I/P-FG, O/P-FG: 1500VAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG : >100M Ohms |
EMI | Compliance to EN55011 Class B, EN55022 Class B, EN61000-3-2, EN61000-3-3 |
EMS | Compliance to EN61000-4-2 Level 3, 8KV, EN61000-4-2 Level 2, 4KV |
EN61000-4-3 Level 2, 3V/m , EN61000-4-3 Level 3, 10V/m | |
EN61000-4-4 Level 2, 1KV/5KHz, EN61000-4-4 Level 3, 2KV/5KHz | |
EN61000-4-5 Level 4, 2KV/Line-Line, 4KV/Line-Earth | |
EN61000-4-6 Level 2, 3Vrms/m, Level 3, 10Vrms/m | |
EN61000-4-8 Level 2, 3A/m, EN61000-4-8 Level 3, 10A/m, EN61000-4-11 Compliance | |
ENV50204 Level 2, 3V/m, 900MHz, ENV50204 Level 3, 10A/m, 900MHz | |
MTBF | 262,100 hours min MIL-HDBK-217F |
Dimensions | 177.8 x 107.2 x 35.5mm |
- CB
- CE
- CSUUS
- MEDICAL
- PFC
- TUVMedical
Products in this range
Part number | Power (watts) | Voltage (max/rated) | Current (amps) | R&N (mV) | Efficiency (%) | |
---|---|---|---|---|---|---|
MPT-200A | 200W | 12V | 20A | 120mV | 80% | Request Quote |
MPT-200B | 200W | 12V | 20A | 120mV | 80% | Request Quote |
MPT-200C | 200W | 15V | 5A | 150mV | 80% | Request Quote |
MPT-200D | 200W | 12V | 20A | 180mV | 81% | Request Quote |