MEAN WELL Products
Additional information
| Standards | CE  | 
		
|---|---|
| Type | DC/DC  | 
		
| Outputs | Single  | 
		
| Inputs | 36~72Vdc  | 
		
- 2:1 wide input range
 - Short circuit, over load, over voltage, over temperature protections
 - 1500VDC I/O isolation
 - Cooling by free air convection
 - 100% full load burn-in test
 - Design refers to LVD
 
| Input Voltage | 36 ~ 72VDC | 
| Inrush Current | 45A/48VDC | 
| Line Regulation | ±0.5% | 
| Load Regulation | ±1.0% | 
| Set Up, Rise Time | 300ms, 50ms at full load | 
| Over Load Protection | 105% ~ 135% rated output power | 
| Shut down o/p voltage, re-power on to recover | |
| Over Voltage Protection | Protection type: Shut down o/p voltage, re-power on to recover | 
| Over Temperature Protection | 95°C±5°C TSW1 detect on main power transistor | 
| Shut down o/p voltage, recovers automatically after temp goes down | |
| Working Temperature | -20°C ~ +60°C (refer to output load derating curve) | 
| Working Humidity | 20 ~ 90% RH non-condensing | 
| Storage Temperature, Humidity | -40°C ~+85°C, 10 ~ 95% RH | 
| Temperature Coefficient | ±0.03% /°C (0 ~ 50°C) | 
| Vibration | 10 ~ 500Hz, 2G 10min./1 cycle, 60 min. each along X, Y, Z axes | 
| Withstand Voltage | I/P-O/P:1.5KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC | 
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | 
| Safety Standards | Design refers to LVD | 
| EMI conduction & radiation | Compliance to EN55022 (CISPR22) Class B | 
| EMS immunity | Compliance to EN61000-4-2,3,4,6,8; ENV50204 Heavy industry level, Criteria A | 
| MTBF | 218.2K hrs min. MIL-HDBK-217F (25°C) | 
- CE
 
Products in this range
| Part number | Power (watts) | Voltage (max/rated) | Current (amps) | R&N (mV) | Efficiency (%) | |
|---|---|---|---|---|---|---|
| SD-200C-5 | 200W | 5V | 40A | 100mV | 81% | Request Quote | 
							
                        