?> ?> ?> ?> ?> RPT-160 Series - 160W Triple Output Open Frame Medical Power Supply
escort bayan fethiye kuşadası escort bayan escort bayan bodrum

MEAN WELL Products

HomeMEAN WELL ProductsMedical Power Supply160W Triple Output Open Frame Medical Power Supply

RPT-160 Series - 160W Triple Output Open Frame Medical Power Supply

Email

Description

RPT-160 Series is a triple output power supply that can fulfill the requirements of general medical or industrial applications while the green RPTG-160, with additional PS-ON control, 5V/0.8A standby output and 0.75W of no-load-power-consumption can be implemented into all kinds of end systems.

Additional information

Standards

CB, CE, CSUUS, PFC, MEDICAL, TUVMedical

Type

AC/DC

Outputs

Triple

  • Universal AC input
  • Built-in active PFC function
  • Short circuit, over load, over voltage, over temperature protections
  • 5"x3" compact size
  • Free air convection for 100W and 145W with 20.5 CFM forced air
  • With power good and fail signal output
  • Built-in remote sense function for 5~15V
  • No load power consumption under 0.75W by PS-ON control (Optional)
  • Standby 5V@0.8A with Fan/0.6A without Fan (Optional)
  • Approval: UL / CUL / TUV / CE / CB
  • Medical applications
  • IT applications
Input Voltage90 ~ 264Vac 127 ~ 370Vdc
Input Frequency47 ~ 63Hz
Power FactorPF>0.93/230Vac PF>0.98/115Vac at full load
Input Current1.8A/115Vac 0.9A/230Vac
Inrush Current35A/115Vac 70A/230Vac, cold start
Leakage CurrentEarth leakage current <300uA/ 264Vac, Patient leakage current <100uA/264Vac
Set Up, Rise Time1200ms, 30ms/230Vac 2500ms, 30ms/115Vac at full load
Hold Up Time16ms/230Vac/115Vac at full load
Voltage Adjustment Range5 ~ 5.5V, CH1 output only
Over Load Protection105 ~ 135% rated output power
Hiccup mode, recovers automatically after fault condition is removed
Over Voltage Protection5.75 ~ 6.75V, CH1 output only
Shut down o/p voltage, re-power on to recover
Over Temperature Protection105°C (TSW1) detect on heatsink of power transistor
90°C (TSW2) detect on heatsink of power transistor
(TSW1)Shut down o/p voltage, recovers automatically after temperature goes down
(TSW2)Shut down o/p voltage, re-power on to recover
5V Standby5VSB : 5V@0.6A without Fan, 0.8Awith Fan 20.5CFM ; tolerance ±2%, ripple : 50mVp-p(max.)
PS-ON Input Signal (Optional)Power on: PS-ON = Hi or >2V; Power off : PS-ON = Low or <0.5V
Power Good/Power Fail500ms>PG>10ms PF>1ms
Working Temperature-20°C ~ +70°C (Refer to output load derating curve)
Working Humidity20 ~ 90% RH non-condensing
Storage Temperature, Humidity-40°C ~ +85°C, 10 ~ 95% RH
Temperature Coefficient±0.03%/°C (0 ~ 50°C)
Vibration10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Withstand VoltageI/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25/°C 70% RH
Safety StandardsUL60601-1, TUV EN60601-1 approved
EMCCompliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B; EN61000-3-2,-3; ENV50204;
EN61000-4-2,3,4,5,6,8,11; EN55024, EN60601-1-2, EN61204-3, medical level, Criteria A
MTBF191.4Khrs min. MIL-HDBK-217F (25°C)
Dimensions127 x 76.2 x 34.6mm
  • CB
  • CE
  • CSUUS
  • MEDICAL
  • PFC
  • TUVMedical