MEAN WELL Products
PLN-30 Series - PLN-30 Series 30W Single Output UL1310 Class 2 IP64 LED Power Supply

30W Single Output UL1310 Class 2 IP64 Power Supply
Description
These limited power sources comply with UL1310 class 2 that under any situation the output power will remain less than 100VA or 5A. This will significantly reduce the hazardous condition exposed to the technicians who execute the construction or maintenance of the LED lighting system. The IP64 enclosure design can protect the electronic components against dust and moisture and makes them suitable for use at indoor or outdoor locations. Thanks to the simplified single stage PFC topology, the required high power factor, as well as the class C harmonic level for the lighting industry, can be achieved economically. Efficiency’s of PLN-30 series are as high as 86% and hence can operate between -30°C ~ +50°C by only free air convection inside the fully covered plastic enclosure. Standard functions include short circuit, over load, over voltage, and over temperature protections. The adjustable output voltage and current level enables the fine tuning of the PSU to comply with the requirement of LED characteristics.
Additional information
Standards | CE |
---|---|
Type | AC/DC,Constant Current,LED Driver |
Range Power | |
Outputs | Single |
Input Voltage | 90 ~ 264Vac 127 ~ 370Vdc |
Input Frequency | 47 ~ 63Hz |
Power Factor | PF>0.9 at 75 ~ 100% load, 115Vac / 230Vac |
Input Current | 0.4A/115Vac 0.2A/230Vac |
Inrush Current | 40A/230Vac |
Leakage Current | 0.5mA/240Vac |
Output Voltage Adjustment Range | -5% ~ 10%. Can be adjusted by internal potential meter SVR1 |
Current Adjustment Range | 3% ~ -25%. Can be adjusted by internal potential meter SVR2 |
Output Voltage Tolerance | ±10% |
Line Regulation | ±3.0% |
Load Regulation | ±5.0% |
Set Up Time | 1500ms / 230VAC 3000ms / 115VAC at full load |
Over Current Protection | 100 ~ 110% |
Constant current limiting, recovers automatically after fault condition is removed | |
Short Circuit Protection | Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage Protection | Shut down o/p voltage, re-power on to recover |
Over Temperature Protection | 95°C ±5°C (TSW1) |
Shut down o/p voltage, re-power on to recover | |
Working Temperature | -30°C ~ +50°C (Refer to output load derating curve) |
Working Humidity | 20 ~ 90% RH non-condensing |
Storage Temperature, Humidity | -40°C ~ +80°C, 10 ~ 95% RH |
Temperature Coefficient | ±0.06%/°C (0°C ~ 50°C) |
Vibration | 10 ~ 500Hz, 2G 12min./1 cycle, period for 72min. each along X,Y, Z axes |
Withstand Voltage | I/P-O/P:3.75KVAC |
Isolation Resistance | I/P-O/P:100M Ohms/500VDC 25°C 70%RH |
Safety Standards | TUV EN61347-1, EN61347-2-13, CAN/CSAC22.2 No. 223-M91(except for 48V), IP64 approved |
EMC | Compliance to EN55015; EN61000-3-2 Class C (pin25W), Class D (>70% load) ; EN61000-3-3; |
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, Light industry level, criteria A | |
MTBF | 621.4Khrs min. MIL-HDBK-217F (25°C) |
Dimensions | 145 x 47 x 30mm |
- CE
Products in this range
Part number | Power (watts) | Voltage (max/rated) | Current (amps) | R&N (mV) | Efficiency (%) | |
---|---|---|---|---|---|---|
PLN-30-12 | 30W | 12VDC | 3A | 2mV | 83% | Request Quote |
PLN-30-15 | 30W | 15VDC | 2A | 3mV | 84% | Request Quote |
PLN-30-20 | 30W | 20VDC | 2A | 3mV | 84% | Request Quote |
PLN-30-24 | 30W | 24VDC | 1A | 3mV | 85% | Request Quote |
PLN-30-27 | 30W | 27VDC | 1A | 2mV | 85% | Request Quote |
PLN-30-36 | 30W | 36VDC | 1A | 5mV | 86% | Request Quote |
PLN-30-48 | 30W | 48VDC | 1A | 4mV | 86% | Request Quote |
PLN-30-9 | 30W | 9VDC | 3A | 3mV | 80% | Request Quote |